胶粘剂应用方案 · 东莞东立电子材料
Home / Insights / Industry Knowledge
Industry Knowledge

Thermal Pad, Gel or Grease? A Comparison Guide to Thermal Interface Materials

Published:2026-09-13Category:Industry Knowledge

In thermal design for power devices and battery packs, the chip or cell and its heatsink may look firmly attached, but less than 10% of two solid surfaces actually touch — the rest is air trapped in microscopic gaps, and air conducts at just 0.026 W/m·K. A thermal interface material (TIM) replaces that air with a conductive path. The catch: TIMs come as pads, gels and greases, and picking the wrong family often hurts more than picking the wrong conductivity number.

What each family looks like

Thermal pads are pre-formed silicone sheets with a fixed as-shipped thickness, compressed into the gap by assembly pressure — the simplest to use, with straightforward tolerance control.

Thermal gels are paste-like materials dispensed by equipment. Before cure they flow and conform to warped surfaces; after cure they become soft solids. Low-bleed one-part post-cure gels are well suited to volume production lines.

Thermal greases never cure and stay paste-like, offering the lowest thermal resistance — but under high temperature and pump-out they dry out and migrate over time, so they suit ultra-low-resistance, periodically maintained assemblies.

DimensionPadGelGrease
Gap range0.5 – 5 mm0.2 – 3 mm< 0.3 mm
Assembly pressureSustained clampLowLow
Tolerance absorptionPoor (single thickness)Good (flows)Good
Long-term reliabilityGoodGood (low-bleed grades)Dries / migrates
ReworkEasyPeelableClean & reapply
AutomationManual placementDispensing lineStencil / dispense
Typical useCell-to-coldplateMulti-die modulesCPU / GPU

Three field rules of thumb

One overlooked fact: resistance is not conductivity

Many selections fixate on the W/m·K number, but total interface resistance = bulk resistance (thickness ÷ conductivity) + contact resistance at both faces. A 1 mm pad at 5 W/m·K already carries ~0.2 cm²K/W of bulk resistance, and insufficient clamp pressure can add just as much again. So check compression ratio and hardness for pads, wettability and thixotropy for gels, and printed thickness control for greases — conductivity without assembly context is meaningless.

When in doubt, send us the mechanical parts and test under real conditions: comparing junction or case temperatures of 2–3 candidate materials beats any datasheet. Dongli keeps samples of all three families in stock.